J 900 SERIES MICROSCOPE

Equipped with universal infinity independent plan achromatic optical system, chromatic aberrations and curvature of field are both ideally corrected over the field of view.

Ergonomic design: The position of coaxial coarse and fine focus knob can be adjusted

High eye-point, Wide field of view eyepiece, and its diopter is adjustable. Standard 10X eyepieces view-field can be chose between 20mm and 22mm. And high eye-point eyepiece with the distance up to 21mm view-field can bring you wider vision and more comfortable feeling.

NILPA CONSULTANCY

2B-SHOBHANA APARTMENT,

K V ROAD, OFF W S ROAD,

DAHISAR (EAST)

MUMBAI - 400 068

INDIA

 

Phone:+91 22 2828 2830

Fax: +91 22 2828 0397

E-mail: info@nilpaconsultancy.in

Specification

J 900B

J 900T

Optics System

Infinity Independent Plan Achromatic Optical System F=200mm

Viewing Head

Seidentopf binocular tube, Interpupillary distance 52~75mm, 30°inclined, 360° rotateable, diopter adjustable.

 

Seidentopf binocular tube, Interpupillary distance 48~75mm, 30°inclined, 360° rotateable, diopter adjustable.

 

Seidentopf trinocular tube, Interpupillary distance 52~75mm, 30°inclined, trinocular light is split 20/80 by a high quality prism, diopter adjustable.

 

 

Seidentopf trinocular tube, Interpupillary distance 48~ 75mm, 30°inclined ,trinocular light is split 20/80 by a high quality prism,diopter adjustable.

 

 

Eyepiece

WF10X/20mm, High eye-point up to 21mm.

●●

●●

WF10X/22mm, High eye-point up to 21mm, WF16X/14mm

WF10X/20mm (Pointer), High eye-point up to 21mm. WF10X/22mm (Pointer), High eye-point up to 21mm.

Reticule Eyepiece: CROSSWF10X/20mm, CROSSWF10X/22mm

Centering Telescope                            CTE

Nosepiece

Quadruple, inward

quintuple, inward

Objectives

Plan Achromatic 2X/0.06, WD=3.55mm

Plan Achromatic 4X/0.10, WD=12.31mm, 10X/0.25, WD=5.03mm, 40X/0.65(S), WD=0.72mm, 100X/1.25 (S,O), WD=0.17mm

Plan Achromatic 20X/0.40, WD=2.71mm

Plan Achromatic 60X/0.80(S), WD=0.69mm

Phase-Contrast (positive or negative) Objectives

PH Plan Achromatic 10X/0.25, WD=5.03mm, 20X/0.40, WD=2.71mm, 40X/0.65, WD=0.72mm, 60X/0.80, WD=0.69mm, 100X/1.25(S,O), WD=0.17mm

Phase-Contrast Slide

10X PH, 20X PH, 40X PH, 60X PH, 100X PH

 

 

 

Condenser

Multi-Purpose Phase contrast Condenser: NA:1.25, Phase contrast observation from 10X to 100X and Dark-field observation from 10X to 40X is allowed

Abbe condenser: NA=1.25, with iris diaphragm, with socket to accommodate PH-slide. Condenser center adjustable, color-coded diaphragm scale markings cooresponded with the objectives of different powers.

Dark Condenser(Dry)

Focusing

Coaxial coarse and fine focusing knob, height adjustable.

Electrical Parts

6V/20W Halogen Bulb: Input: 100~240V 0.5A, 47~63Hz, Output: 6V 3.4A, Fuse: 3.15A, 250V, FΦ5×20mm, Halogen Bulb Socket: G4

6V/30WHalogen Bulb Input: 100~240V 0.5A, 47~63Hz, Output: 6V 3.4A, Fuse:3.15A, 250V, FΦ5×20mm, Halogen Bulb Socket: G4

3W LED Bulb

C-Mount

1X, 0.5X, 0.25X

 

Digital Camera Adapter

(Please advice your digital camera model in advance)

 

Filter

Blue

Green, Yellow, Grass Glass

Filter Holder

Filter Holder: (Attached to the Kholer) for more than one filter.

Polarization kits

Analyzer Slide

Polarizer Slide

Fluorescence Attachment

Hg Fluorescence Lamp house 100W

Mercury lamp 100W (Osram)

Filter Turret, UV Shield

Hg Power Source House 100W

UV Excitaion Filter , V Excitation Filter , B Excitation Filter , G Excitation Filter

Illumination

6V 20W Osram Halogen Bulb

With field diaphragm (inside Kohler)

6V 30W Osram Halogen Bulb

3W LED Bulb

Two sides LED (3W Each side;4pcs each side;0.1w each pcs)

Immerse Oil

8ml

Allen Screw Driver

Φ2mm